| DTR Reason Code | Stoppage Title & Bengali Translation | Machine / Mold | Operator Log / Handover Note | Duration | Logged Time | Reported By | |
|---|---|---|---|---|---|---|---|
| DTR-02 | Cutting Tool Breakage / Special Insert Shortageকাটিং টুলস বা ইনসার্ট ভেঙে যাওয়া বা সংকট | VMC-02MD-2026-001 | "Sandvik R390 16mm carbide tip chipped while milling hardened 718H rib step." | 30 mins | 2026-10-22 11:15 | Abdul Alim | |
| DTR-01 | Drawing / CAD Revision Missing or Ambiguityঅস্পষ্ট বা অনুপস্থিত ড্রয়িং / রিভিশন অমিল | FIT-01MD-2026-001 | "Awaiting CAD team confirmation for v1.1 parting line clearance update." | 25 mins | 2026-10-22 14:00 | Master Fitter Noor | |
| DTR-05 | Workpiece Clamping & Truing Delay / Zero-Point Fixtureক্ল্যাম্পিং ও ট্রুইং ডায়াল সেটআপ বিলম্ব | VMC-03MD-2026-002 | "Magnetic chuck parallel alignment required 0.005mm dial indicator truing." | 20 mins | 2026-10-23 09:20 | Zahidul Islam | |
| DTR-07 | Power Interruption / Generator Transferবিদ্যুৎ বিভ্রাট বা জেনারেটর সংযোগ | VMC-01MD-2026-001 | "Sub-station switchgear maintenance transfer to 500kVA Cummins generator." | 15 mins | 2026-10-24 16:10 | Kabir Hossain |